LLA LED Class 2 Power Supply Metal Enclosure

● CSA SPE-1000 Certified

● Ready to 120V Connect

● Save time, reduce boxes, and ensure safe, professional installations

● Engineered for sign shops and installers who demand quality.

● Indoor use only

● For signage systems

● For horizontal and vertical mounting

● Disconnect powers before service or opening!

● 7-year warranty (*LLA LED Power Supplies)

How much you can save your costs 

Specifictions

InputDual 60W
100 ~ 240VAC 2.6A Max. 50/60Hz
277VAC 1.0 Max. 50/60Hz

Single 180W
100 ~ 277VAC 1.87A Max. 50/60Hz
OutputDual 60W
12VDC 5.0A x 2 120W

Single 180W
Triple 60W each 12VDC 5.0A x 3 180W
AtmosphereDual 60W
Ta: 40°C Tc: 90°C

Single 180W
Ta: -25°C ~ 40°C Tc: 80°C
Electrical Ready to 120V Connect
Certificates CSA SPE-1000 Certified
UsageIndoor location only
Enclosure materialG90 galvanized steel
Dimension9" × 12" × 2.5"

Features
Pre-wired CSA-certified grounding wire (AWG 14)

Pre-wired cUL-certified toggle-switch with two lead-wires (AWG 18)

Pre-drilled (4) x mounting holes and (14) x standard conduit knockouts
Warranty7 years (*LLA LED Class2 Power Supplies)
Power OptionsTwo (2) x 60W LLA Class2 PSUs

One (1) x 180W LLA Class2 PSU

● READ AND FOLLOW ALL SAFETY INSTRUCTIONS provided on or with this enclosure.

● Installation and electrical wiring must be performed by qualified person(s) in accordance with all applicable local and national codes and standards, including fire-rated construction requirements.

● WARNING: Risk of Electric Shock. Mount the unit at a height greater than 12 inches (30 cm) above ground surface.

● WARNING: Risk of Fire. Installation involves special wiring methods to route wiring through a building structure. Consult a qualified electrician.

● Turn power OFF at the fuse or circuit breaker panel before installation, inspection, servicing, or removal.

● For INDOOR USE ONLY.

● The power supply must be properly grounded before operation. This enclosure is intended for installation in accordance with Article 600 of the National Electrical Code (NFPA 70) and all applicable local codes. Proper grounding and bonding of the sign are required.

● SAVE THESE INSTRUCTIONS. This manual contains important safety and operating instructions for the power unit.

● WARNING: Risk of Scratching or Injury. Always wear protective gloves when installing the LLA PRO BOX.

● Mounting Location. Install the LLA PRO BOX in an accessible indoor dry location only. Securely fasten the enclosure to a solid mounting surface.

● Mounting Orientation. The enclosure may be mounted vertically or horizontally (see approved orientations). Do not install in areas subject to standing water or flooding. If installed above a suspended ceiling, do not use the ceiling grid for support.

● Power Supply Limitation. Do not install additional LED power supplies inside the PRO BOX. Overloading the enclosur e will result in overheating and possible equipment failure.

● Conduit & Connectors. Use weatherproof conduit and connectors for all primary power entry and exit points, even in dry locations.

● Wiring Clearance. Route primary wiring to maintain required spacing inside the enclosure. Orient wire connections toward the bottom of the PRO BOX.

● Electrical Connections. Connect the free black wire from the switch to the service line (hot) wire. Connect the free white wire to the service neutral. Securely connect the service ground to the pre-bonded green grounding wire. Form a drip loop after each wire enters the enclosure.

● Input Voltage. 100–277 VAC input only.

● Openings. Do not leave any wiring holes open. Seal all unused openings properly.

● Cover Installation. Secure the cover using the provided metal screws. Do not operate the unit without the cover installed.